Products Design & Engineering Manufacturing & Quality Power Transmission Engineering Services Outsourcing
Equipment
Equipment:
Air Cooled Vacuum Steam Condensers
Air Cooled Heat Exchangers
Process Gas Coolers
Cooling Water Systems
Transformer Oil Coolers
Condensing & Feed water heating systems
Finned Tubes:
Extruded Aluminium Bi- Metallic Fin Tubes
Grooved & Embedded Aluminium Fin Tubes
Wrap on 'L' Footed and overlapped 'LL' Aluminium and Copper Fins
Crimped copper Fin Tubes
Wire wound copper and stainless steel Fin Tubes
Components:
Internal Turbulators
Aluminium Louvers
Transformer Oil Cooler

The air cooled oil coolers are designed to dissipate heat from the oil of generator Transformer, Distribution Transformer, Smoothing Reactors and Locomotive Transformers.

Specially designed internal turbulators are provided for effective heat transfer from the viscous oil.

 
Transformer Oil Cooler
Transformer Oil Cooler

Service

Transformer oil.

 

Finned Surface

Carbon steel or brass tubes with external aluminium "L" or "LL" fins and internal stainless steel turbulators.

 

Configuration

Included draft or forced draft axial flow in step of 1, 2, 3, 4 or 5 fans per module.

 

Mounting

Tank mounted or externally skid mounted as requested.

 

Noise Level

70 to 80 dBA Lower noise level design available on request

 
DOUBLE TUBE HEAT EXCHANGER
 
Design:
 
This design of annular tube construction has the following features:
   Prevents water leaking into oil stream.
   Allows automatic seepage of leaked water.
   Alarm and indication in event of water leakage.
 
Construction:

The inner tube made of Cupro-nickel material is expanded into outer tube sheet facing the water surface. The outer tube which is press fit on the inner tube is of copper material have and longitudinal grooves along the length on the inner side circumferentially. The outer surface of these tubes have integral low fins for enhancement of heat transfer on the oil side and is expanded into the inner tube sheet.

The leaked water is collected in the recess provided between the outer and inner tube Sheet. Once filled, the water is sensed by the water leakage probe provided at the bottom and signal / alarm is indicated on the controller unit mounted on the shell of the cooler. The leaked water can then be drained out from the drain plug. This feature ensures safety to the transformer unlike the conventional oil cooler where oil and water mixing takes place in the event of leakage.